SAFETY ALERT NO. 213:
DIVING INCIDENT - NEAR MISS
|
|
Country: null
|
|
Location: OFFSHORE : Other offshore
|
|
Release Date: —
|
Time incident occurred: —
|
|
Type of Activity: Diving, Subsea, ROV
|
|
Type of Injury: null
|
Function: null
|
|
Applicabale Filter Categories: System/Equipment failure
|
|
|
- Surface air dive to -34fsw
- Bail-Out bottle contained mixed gas
- Diver bumps control valve allowing gas to hat
- Supervisor immediately switches to HP back up air
- Abort dive - diver to surface - no harm
|
What Went Wrong?:
- Content not analyzed - only checked for pressure
|
Corrective actions and Recommendations:
- Bail-Out contained 14% HeO2– emptied-charged with air
- Bail-Out bottles will be analyzed for content at the start of project
- Bail-Out bottles that are used for mixed gas will be:
- Supplied by the dive contractor (no personal bottles)
- All bottles will be color coded
- All bottles will be labeled with % of mix
- Pre-Dive Checklist will include a Bail-Out Drill
|
|